For laboratory and research use only. Not for human consumption.Research use onlyNot for human consumption

How to check whether a peptide certificate of analysis is genuine

A certificate of analysis (COA) is only useful if it is the real report for the batch in hand. This guide sets out verification steps a laboratory can carry out itself, from matching the batch number to confirming the report with the laboratory named on it. It is written for laboratory research only. For a field-by-field walk through a certificate, see How to read a certificate of analysis.

What “genuine” means for a COA

A genuine certificate is an unaltered report, issued by the laboratory it names, for the batch it names. Pharmaceutical quality guidance gives a useful reference point, even though it is written for drug ingredients rather than research materials. ICH Q7 expects authentic certificates to be issued for each batch.[1] It expects a certificate to give the batch number and the date of release,[1] to list each test performed with its acceptance limits and numerical results,[1] and to be dated and signed.[1] Where a certificate is reissued by an agent or broker, ICH Q7 expects it to show the name, address and telephone number of the laboratory that performed the analysis, and to refer to the original batch certificate.[1] ICH Q7 also says the reliability of certificates should be checked at regular intervals.[1] The steps below apply the same idea to a research peptide certificate.

Verification steps

1. Match the batch number to the vial

Find the batch or lot number on the vial label and compare it with the certificate, character by character. A different number, such as the lab’s own sample or lot reference, is a warning sign unless the seller shows how it maps to the batch on the vial. Watch for look-alike characters such as 0 and O, or 1 and I. The product name and strength on the certificate should also match the label. A certificate for the product in general, rather than for the batch in hand, does not describe that vial.

2. Check that a laboratory, a method and a date are named

The certificate should name the laboratory that performed the testing, a method for each result, and the test date. A result with no method cannot be compared or repeated, and a report with no date cannot be placed in time. Check that the date is plausible for the batch: a report dated before the batch could have existed is a reason to ask questions.

3. Check that results are measured figures with a named method

Purity is commonly reported from high-performance liquid chromatography (HPLC) and identity from mass spectrometry; they answer different questions. For an identity test, ICH Q2(R2) states that a critical aspect is showing that the procedure can identify the analyte based on unique aspects of its molecular structure or other specific properties.[2] Look for a figure next to each test, not a phrase such as “high purity”. The guide HPLC purity vs mass spec identity explains the difference.

4. Compare the copy with the supplier’s own lookup

A PDF sent by email or shown in a screenshot is a copy. If the supplier publishes a certificate lookup, open it by entering the batch number or scanning the code on the label, and compare the two documents field by field. Any difference between the copy and the published record is a reason to stop and ask.

5. Confirm with the named laboratory

Contact the laboratory named on the certificate and ask it to confirm that it issued the report and that the report covers that batch. Find the laboratory’s contact details yourself, for example from its own website, rather than relying on a phone number, email address or link printed on the certificate, since those details are part of the document being checked. Give the laboratory the report number if there is one, the batch number and the test date, and ask whether the results match its records.

6. Look for signs of editing

Check whether fonts, spacing, alignment or image quality change partway through the document, especially around the batch number, the date and the results. A certificate that looks edited is not evidence of a problem with the material on its own, but it should be confirmed with the laboratory before it is relied on.

Red flags

Each of these is a reason to ask more questions. None proves a problem with a material on its own, and none is evidence of quality either.

  • Generic certificate: one document shown for every batch, or no batch-specific details.
  • Reused certificate: the same report, report number or results appearing for more than one batch.
  • Batch mismatch: the name or strength differs from the label, or the batch number differs and the seller does not show how the lab’s own reference maps to it.
  • No laboratory, method or date: nobody named as having done the testing, or no way to tell how or when.
  • Implausible or stale date: a test date that does not fit the batch.
  • Phrases instead of figures: wording such as “pharmaceutical grade” in place of a measured result.
  • Signs of editing: layout or fonts that change within the document, or a copy that differs from the supplier’s published record.
  • Unconfirmed by the laboratory: the named laboratory cannot be reached by details you found yourself, or cannot confirm the report.

Quick checklist

  • Batch number on the certificate matches the vial, character by character, or the seller shows how the lab’s own reference maps to it.
  • Product name and strength match the label.
  • Laboratory, method and test date are all named.
  • Each result is a measured figure with its method.
  • The copy matches the supplier’s published lookup.
  • The named laboratory confirmed the report and batch, using contact details you found yourself.
  • No signs of editing.

Example: how one supplier’s certificates can be checked

Every batch Atrix offers is tested by an independent third-party laboratory, and its certificate names the laboratory, the method and the date.

Atrix names the laboratory on each certificate, so the laboratory to contact for step 5 is the one shown on that batch’s certificate.

Atrix requires purity of 99% or higher (≥99%) for every peptide batch, reported on its certificate with the test method named.

The Atrix label carries the batch number under a QR code that opens that batch’s certificate.

To find the certificate for an Atrix vial for step 4, scan the QR code on the vial, or enter the batch number printed under it in the COA library.

The QR code opens that batch’s certificate in the Atrix COA library on any phone, with no account needed.

Atrix publishes the certificate of every batch it offers, and keeps it after the batch sells out.

All Atrix materials are for laboratory and in vitro research only, not for human or veterinary use.

For a wider set of checks on a supplier, see How to verify a research peptide supplier.

In the FAQ: Who tests each batch?

FAQ

How can I tell if a peptide COA is real?

Match the batch number, name and strength to the vial, check that a laboratory, a method and a date are named, compare the copy with the supplier’s own lookup, and confirm the report with the named laboratory using contact details you found yourself.

Why should I find the laboratory’s contact details myself?

The contact details printed on a certificate are part of the document being checked. Details taken from the laboratory’s own website or another independent listing let the laboratory confirm the report without relying on the certificate itself.

Does a QR code or lookup prove a certificate is genuine?

No. A lookup shows the record the supplier publishes, and a match between your copy and that record is a useful check. Confirmation that the report and batch are genuine comes from the laboratory that issued it.

What are the most common COA red flags?

A generic or reused certificate, a batch number that does not match the vial, a missing laboratory, method or date, phrases in place of measured figures, and signs of editing within the document.

Sources

  1. ICH Q7: Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients (7.31; certificates of analysis 11.40 to 11.44). database.ich.org (PDF) (also published by FDA as guidance for industry: fda.gov)
  2. ICH Q2(R2) Guideline: Validation of Analytical Procedures (2023), section 3.1.2.1 Identification. database.ich.org (PDF)

Researchers with an account can see each product's batches and certificates.