How to read a certificate of analysis (COA) for research peptides
A certificate of analysis, or COA, is the document a laboratory researcher checks before relying on a batch of material. This guide walks through each part of a COA, shows how to match a certificate to the vial in hand, and lists the signs of a certificate that cannot be relied on. It is written for laboratory research only.
The parts of a COA
Read a certificate from top to bottom and check that each of the parts below is present and specific.
1. Product identity
The certificate should name the material it describes, exactly as it appears on the vial label. If the name on the certificate and the name on the label differ, the certificate does not describe that vial.
2. Strength
The strength is the stated amount of material in the vial. Compare it with the strength printed on the label. A certificate for a different strength is a different certificate, even when the product name matches.
3. Batch or lot number
The batch number (also called a lot number) ties the certificate to one production run. It is the most important line for matching, because it is the only field that separates one run of the same material from another. Look for a full identifier, not a range, a placeholder or “see label”. See batch and lot numbers.
4. Test method
The method line says how each result was obtained. Check that a method is named for each result, for example HPLC or mass spectrometry, rather than left blank or described only as “tested”. A result with no named method cannot be compared or repeated. See what HPLC and mass spectrometry each show.
5. Purity result
The purity line reports the measured result for the batch. Check three things: that it is a measured figure rather than a phrase such as “high purity”, that it is reported for this batch, and that the method next to it is named. See what a purity percentage means, and why it is not net peptide content.
6. Laboratory
The certificate should name the laboratory that performed the testing. A named laboratory gives a reader someone to contact about the report. Where the certificate names a laboratory other than the supplier, note it; where it names none, read the report with caution.
7. Date
The test date shows when the analysis was performed. Check that it is present and that it is consistent with the batch: a certificate dated before the batch number could exist, or with no date at all, is a reason to ask questions.
Worked example
The values below are placeholders, not a real certificate.
| Field | What the certificate shows | What to check |
|---|---|---|
| Product | [Product name] | Same name as the vial label |
| Strength | [Strength as labelled] | Same strength as the vial label |
| Batch / lot | EXAMPLE-0000 | Same characters as the number printed on the vial |
| Method | [Named method] | A method is named for each result |
| Purity | [Measured figure, %] | A figure, not a phrase |
| Laboratory | [Laboratory name] | A laboratory is named |
| Date | [Test date] | A date is present and plausible |
Matching a COA to the vial in hand
- Find the batch number on the vial label.
- Open the certificate for that batch number, not a certificate for the product in general.
- Compare the batch number character by character. Look closely at characters that are easy to confuse, such as 0 and O, or 1 and I.
- Compare the product name and the strength with the label.
- If any of these fields differ, the certificate is not the certificate for that vial.
Common questions about finding a certificate are answered in the FAQ.
To check that a certificate is genuine, see How to check whether a peptide certificate of analysis is genuine. If a certificate gives a storage condition, compare it with the label: see storing sealed lyophilized vials.
Red flags of a weak COA
- Generic: one certificate offered for every batch of a product, or a document with no batch-specific details.
- No batch number: the certificate cannot be tied to any vial.
- No laboratory: nobody is named as having performed the testing.
- No method: results appear with no named method behind them.
- No date: there is no way to tell when the testing took place.
- Phrases instead of figures: wording such as “pharmaceutical grade” or “high purity” in place of a measured result.
- Mismatches: the name or strength on the certificate differs from the label, or the batch number differs and the seller does not show how the lab’s reference maps to it.
A certificate with one of these gaps is not proof of a problem with the material, but it is not evidence of quality either. Ask the supplier for the batch-specific certificate.
Example: a batch-linked certificate library
At Atrix Research Labs, a certificate of analysis is the lab report for one batch: the product, its strength, a batch or sample reference and the test results. It has to match the product and the strength, name a batch identifier that matches our batch, name its test method, and report purity of 99% or higher (≥99%).
Every batch Atrix offers is tested by an independent third-party laboratory, and its certificate names the laboratory, the method and the date.
Atrix requires purity of 99% or higher (≥99%) for every peptide batch, reported on its certificate with the test method named, and reviews the certificate before the batch is offered.
The Atrix label carries the batch number under a QR code that opens that batch’s certificate.
To find the certificate for an Atrix vial, scan the QR code on the vial, or enter the batch number printed under it in the COA library.
The QR code opens that batch’s certificate of analysis in the Atrix COA library, on any phone, with no account needed.
Atrix publishes the certificate of every batch it offers, and keeps it after the batch sells out.
All Atrix materials are for laboratory and in vitro research only, not for human or veterinary use.
Researchers with an account can see each product's batches and certificates.