For laboratory and research use only. Not for human consumption.Research use onlyNot for human consumption

Storing sealed lyophilized research materials: what the label means

A sealed vial of lyophilized research material arrives with a short storage line printed on its label. This guide explains where that line comes from, what a shelf life or re-test date means, and what to check when a sealed vial arrives at the laboratory. It covers sealed, unopened vials only, and is written for laboratory research only.

Why sealed lyophilized material is kept cold and dry

Temperature

Stability testing shows how the quality of a material changes over time under temperature, humidity and light, and it is the basis for the recommended storage conditions (ICH Q1A(R2), 1.3).

Stability study conditions are not instructions for any particular vial. The storage line on a label is what tells the laboratory how its material is to be kept.

Moisture

Stability studies are run on material in a container closure that is the same as, or simulates, the packaging used for storage and distribution (ICH Q1A(R2), 2.1.4). A storage statement therefore describes the material in its sealed container.

Light

Light exposure is one of the factors stability testing examines, and photostability testing is meant to show that light exposure does not result in unacceptable change (ICH Q1B, A. Preamble). Where a label or certificate names light protection, follow it.

Reading the storage line on the label

The ICH guideline says a storage statement should be established for the labeling, based on the stability evaluation, and that terms such as “ambient conditions” or “room temperature” should be avoided (ICH Q1A(R2), 2.1.10).

When reading a label, check three things:

  1. The temperature range. A specific range, in degrees, rather than a phrase such as “cool place” or “room temperature”.
  2. Any extra condition. For example a note about light, or a note that the material must not be frozen (ICH Q1A(R2), 2.1.10).
  3. The date. A re-test date or an expiry date, where one is printed (ICH Q1A(R2), 2.1.10).

If the certificate of analysis for the batch also gives a storage condition, compare it with the label. If the two differ, ask the supplier before relying on either.

Shelf life and re-test dates

The ICH guideline defines shelf life as the time during which a product is expected to remain within its specification, provided that it is stored under the conditions defined on the container label (ICH Q1A(R2), glossary).

A re-test period is the time during which a substance is expected to remain within its specification when stored under the defined conditions; after it, the batch is re-tested against the specification (ICH Q1A(R2), glossary).

Both are derived from stability data for the specific material (ICH Q1A(R2), 2.1.10). There is no general shelf-life figure for “lyophilized material”: a number only means something for the batch and the storage condition it was established for. Read the date on the label or the certificate, not a chart for a class of materials.

Shipping and temperature excursions

The ICH guideline expects storage conditions and study lengths to cover storage and shipment, and uses accelerated data to evaluate the effect of short-term excursions outside the label storage conditions, such as might occur during shipping (ICH Q1A(R2), 2.1.7).

Whether a given excursion matters depends on that material’s stability data, so it cannot be judged from a general rule.

When a sealed vial arrives at the laboratory:

  1. Check that the vial is intact and the seal is unbroken.
  2. Check that the label is legible, including the batch number and the storage line.
  3. Place the vial in storage that matches the label’s storage line.
  4. Record the arrival date and the batch number in the laboratory’s inventory.
  5. If the package or vial arrived damaged, or the seal is broken, contact the supplier before relying on the material.

Keeping the vial sealed until it is needed

A storage statement and a shelf life describe the material in its sealed container (ICH Q1A(R2), 2.1.4 and glossary). Keep the vial sealed, in the storage the label states, until the laboratory work it is intended for. This guide does not cover anything after a vial is opened.

Example: where the storage condition is shown

Atrix peptides are supplied as a lyophilized powder, as printed on each label.

Atrix peptides are lyophilized, vialed and tested in the USA.

The Atrix label carries the product name, strength and form, vial size, the research-use-only band, and the batch number under a QR code that opens that batch’s certificate.

The storage condition for each Atrix product is listed on its product page.

To find the certificate for an Atrix vial, scan the QR code on the vial, or enter the batch number printed under it.

For what the certificate itself reports, see How to read a certificate of analysis.

All Atrix materials are for laboratory and in vitro research only, not for human or veterinary use.

Frequently asked questions

What storage temperature does a sealed lyophilized peptide need?

The temperature printed on its own label. Storage statements are set from stability data for the specific material, and the ICH guideline has separate categories for refrigerator and freezer storage (ICH Q1A(R2), 2.1.7 and 2.1.10). A general chart cannot replace the label.

What is the shelf life of lyophilized material?

There is no single figure. Shelf life is the time a product is expected to stay within its specification when stored under the conditions on its container label, and it is derived from stability data for that material (ICH Q1A(R2), glossary). Look for the expiry or re-test date on the label or the certificate.

Can sealed lyophilized vials be kept at room temperature?

Follow the label’s storage line. The ICH guideline says storage statements should avoid terms such as “room temperature” and give a specific condition instead (ICH Q1A(R2), 2.1.10). Whether a short time outside that condition matters, for example in transit, depends on that material’s stability data (ICH Q1A(R2), 2.1.7).

Sources

  1. ICH Q1A(R2), Stability Testing of New Drug Substances and Products (sections 1.3, 2.1.4, 2.1.7, 2.1.10 and glossary). database.ich.org (PDF)
  2. ICH Q1B, Photostability Testing of New Drug Substances and Products (A. Preamble). database.ich.org (PDF)