"Third-party tested": what an independent laboratory report covers
"Third-party tested" is a short phrase that can stand for a lot of different things. On its own, it does not say which laboratory did the testing, which tests it ran, on which sample, or when. For a field-by-field walk through a certificate, see How to read a certificate of analysis.
What "third-party tested" can mean
In this guide, "third-party" means a testing laboratory that is a separate organisation from the supplier whose material it tests. That is the most a reader can take from the phrase itself.
Independent is not the same as unconnected
An independent laboratory is usually commissioned and paid by the organisation that sends it the sample. Pharmaceutical quality guidance describes testing laboratories that work this way as contract laboratories: ICH Q7 expects a written contract or formal agreement that defines the quality responsibilities of each party, and expects changes to test methods or specifications to be made only when the contract giver is informed and approves.[5] A commercial relationship between a supplier and a laboratory is therefore normal. What independence adds is a second organisation, with its own staff, records and quality system, standing behind the result.
The laboratory standard ISO/IEC 17025 sets general requirements for the competence, impartiality and consistent operation of laboratories.[4] Among the terms the standard offers for impartiality are "freedom from bias" and "freedom from conflict of interest".[4] A laboratory's impartiality is a property of how it works, not of who pays the invoice.
What the phrase alone does not tell you
"Third-party tested" with nothing else attached does not answer any of these questions:
| Question | Where the answer should be |
|---|---|
| Which laboratory? | The laboratory's name on the report |
| Which tests, by which methods? | A named method next to each result |
| Which sample, from which batch? | The sample description and batch number on the report |
| When? | The test date and report date |
| Is the laboratory accredited for these methods? | The accreditation body's published scope for that laboratory |
| Did the batch meet a specification? | The acceptance criterion next to each result |
The phrase points to a document; the document carries the information.
What an independent laboratory report covers
The laboratory
A report should name the laboratory that performed the analysis. ICH Q7 expects certificates reissued by agents or brokers to show the name, address and telephone number of the laboratory that performed the analysis and to refer to the original batch certificate.[5]
The sample tested
A laboratory report describes the sample the laboratory tested. Whether that sample stands for a whole batch depends on how it was taken. ICH Q7 expects samples to be representative of the batch they are taken from, under a sampling plan that sets the number of containers sampled, the part of the container sampled and the amount taken.[5] The 2017 edition of ISO/IEC 17025 covers all laboratory activities, including sampling.[4][1] When the laboratory did not take the sample itself, its report describes the material it received, and the link between that material and the batch rests on the batch number and on the sender's sampling.
Identity, purity and other results
Each result on a report answers its own question. Identity asks whether the material is the intended molecule; purity asks how much of what the method detected is the main component. ICH Q2(R2) recommends combining two or more analytical procedures where one procedure does not provide enough discrimination, and describes comparing a result with a second, well-characterised procedure that ideally applies a different measurement principle.[6] For peptides, that usually means mass spectrometry for identity and HPLC for purity; see HPLC purity vs mass spec identity. The method used for any batch is the one printed on its certificate. A report that lists one test does not cover the others.
The method, the specification and the result
ICH Q7 expects a certificate to list each test performed, with its acceptance limits and its numerical results.[5] A named method makes a result comparable and repeatable. A specification says what the batch had to meet; the result says what it measured.
The date and the signature
ICH Q7 expects certificates to give the batch number and date, and to be dated and signed by authorised personnel.[5] A dated report places the result in time.
What ISO/IEC 17025 accreditation means
Accreditation is a third-party attestation of competence
ISO/IEC 17025 sets out criteria for laboratories that want to demonstrate their technical competence, an effective quality system and the ability to produce technically valid results.[1] Accreditation is a third-party attestation that a conformity assessment body, such as a testing laboratory, is competent to carry out specific conformity assessment tasks.[1] In one published account, a research institute described accreditation to ISO/IEC 17025 as a widely accepted form of objective evidence of a laboratory's technical competence.[2]
A study of a national medicines quality-control laboratory found fewer nonconformities in audits after ISO/IEC 17025 accreditation than before it, and concluded that accreditation improved the reliability of the laboratory's test reports.[3]
Accreditation has a scope
Accreditation is granted for a defined scope, not for everything a laboratory does. The research institute above was accredited for three named scopes, and its accredited materials, products, types of tests and methods are listed in an accreditation certificate published by the accreditation body.[2] The medicines laboratory in the second study was accredited in eleven test scope areas in 2015 and sixteen in 2018.[3]
The practical point: a laboratory can be accredited for some methods and not others. An accreditation statement on a report supports the results only if the methods that produced them are inside the laboratory's published scope.
ISO/IEC 17025 is not ISO 9001
ISO 9001 is a quality management standard; ISO/IEC 17025 is the standard for the competence of testing and calibration laboratories.[4] A reference to ISO 9001 certification on a laboratory report is not a statement of ISO/IEC 17025 accreditation.
The limits of accreditation
Accreditation is evidence about a laboratory's systems. It is not a guarantee about any single result.
- Assessments are periodic and risk-based. Post-accreditation assessments might not check every clause of ISO/IEC 17025 in detail; they can focus on high-risk areas identified from the laboratory's internal audits.[3]
- Methods are checked against other laboratories. ISO/IEC 17025 expects method performance to be independently assessed through proficiency testing or interlaboratory comparisons.[4] That checks a method over time; it does not re-test a particular sample.
- Scope is per method. An accredited method does not make the laboratory's other methods accredited.[2]
What to check on a report
- A laboratory is named. "Tested by an independent laboratory" with no name gives nothing to look up.
- The batch number matches the vial, character by character, and the report describes the sample tested.
- Each result has a named method, an acceptance criterion and a measured figure.
- The report is dated, and the date fits the batch.
- Any accreditation claim names the accreditation body, and the methods on the report appear in the laboratory's published scope. Look the scope up with the accreditation body, not on the report.
- The standard named is the right one: ISO/IEC 17025 for laboratory competence, not ISO 9001 alone.
Red flags
- The phrase with no report or no laboratory: "third-party tested" with no batch-specific document, or a report with nobody named as having done the testing.
- Accreditation with no body or scope: an accreditation mark or claim with no accreditation body, no certificate number, or methods outside the published scope.
- A report for a different sample: a batch number that does not match the vial, or no sample description at all.
- One test offered as all tests: a purity result presented as proof of identity, or the reverse.
Checklist
- A laboratory is named on the report.
- The batch number on the report matches the vial label.
- Each result names its method, an acceptance criterion and a measured figure.
- The report is dated.
- Any accreditation claim names the body, and the methods are in the laboratory's published scope.
How one supplier names its laboratory
Atrix names no single testing laboratory site-wide: the laboratory is named on each published certificate, so the laboratory to look up for an Atrix batch is the one on that batch's certificate. Before a batch is offered, its certificate has to match the product and the strength, name a batch identifier that matches the batch, name its test method, and report purity of 99% or higher (≥99%). A replaced certificate stays available, marked as a previous version.
FAQ
What does "third-party lab tested" mean?
It means a laboratory separate from the supplier tested the material. The phrase alone does not say which laboratory, which tests, which sample or when; those answers are on the laboratory's report.
What does independent lab testing of peptides cover?
Only what is on the report: the tests the laboratory ran, by the methods it names, on the sample it received, on the date it gives. Identity is usually checked by mass spectrometry and purity by HPLC, and guidance recommends combining procedures where one is not discriminating enough.[6] The method used for any batch is the one printed on its certificate.
Is an ISO/IEC 17025-accredited laboratory accredited for every test it runs?
No. Accreditation covers a defined scope of tests and methods, published by the accreditation body.[2][3] Check that the methods on the report are in that scope.
Does accreditation guarantee that a result is correct?
No. Accreditation is a third-party attestation of a laboratory's competence for specific tasks.[1] Assessments after accreditation can focus on higher-risk areas rather than re-checking every clause[3], and accreditation covers only the methods listed in its scope.[2]
Sources
- da Silva JMB, Chaker J, Martail A, Moreira JC, David A, Le Bot B. Improving Exposure Assessment Using Non-Targeted and Suspect Screening: The ISO/IEC 17025:2017 Quality Standard as a Guideline. J Xenobiot. 2021;11(1):1–15. doi:10.3390/jox11010001. pmc.ncbi.nlm.nih.gov/articles/PMC7838891
- Franić Z, Bituh T, Godec R, Čačković M, Meštrović T, Šiško J. Experiences with the Accreditation of the Institute for Medical Research and Occupational Health, Zagreb, Croatia. Arh Hig Rada Toksikol. 2020;71(4):312–319. doi:10.2478/aiht-2020-71-3449. pmc.ncbi.nlm.nih.gov/articles/PMC7968506
- Okezue MA, Adeyeye MC, Byrn SJ, Abiola VO, Clase KL. Impact of ISO/IEC 17025 laboratory accreditation in sub-Saharan Africa: a case study. BMC Health Serv Res. 2020;20:1065. doi:10.1186/s12913-020-05934-8. pmc.ncbi.nlm.nih.gov/articles/PMC7686690
- Doyle S. QHFSS DNA laboratory – ISO/IEC 17025 conformance and accreditation. Forensic Sci Int Synerg. 2024;8:100449. doi:10.1016/j.fsisyn.2023.100449. pmc.ncbi.nlm.nih.gov/articles/PMC10833102
- ICH Q7: Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients (7.33 sampling; 11.41 to 11.44 certificates of analysis; 16.10 to 16.16 contract manufacturers, including laboratories). database.ich.org (PDF)
- ICH Q2(R2) Guideline: Validation of Analytical Procedures (2023), section 3.1 Specificity/Selectivity. database.ich.org (PDF)
Researchers with an account can see each product's batches and certificates.